How Do Phase-Change Materials Store Heat?
- Intermediate
- Article
- Ages 16+
- 7 min read

A phase-change material (PCM) stores and releases a large amount of heat when it changes phase, for example from solid to liquid, while its temperature stays almost still. That heat is called latent heat. Placed in a wall or attic floor, a PCM softens the heat entering a room, provided its melting point is chosen well.
Contents
- The two axes of the graph (heat added and temperature)
- The two steep parts (no phase change, sensible heat)
- The flat stretch (changing phase, latent heat)
- The two points where the phase change starts and ends
- Latent heat absorbed (bar under the flat stretch)
What you will learn
- Explain how latent heat differs from sensible heat, with numbers to compare.
- Say why a PCM's melting point has to sit close to the room's set-point temperature.
- Compare paraffins with salt hydrates and name the limits of PCMs.
Before you start
It helps to know what temperature is and that adding heat usually warms an object. The remaining ideas are explained in the article.
What is latent heat, and why can it store so much?
Latent heat is the heat exchanged when a material changes phase without changing temperature. The heat associated with a unit mass of material during a phase change is the latent heat of the material. During a phase change the temperature of the material remains constant, and a phase change involves a large amount of heat transfer at a constant temperature, two features attractive for heating, cooling and temperature stabilisation.
Sensible heat is the opposite case: heat that changes temperature while the material stays in one phase. Compare two figures. The latent heat of melting ice into water is 330 kJ/kg, while changing the temperature of water by 10 K takes only 42 kJ/kg of sensible heat. Those figures give a ratio of 330/42, or about 7.9 times. The difference between latent and sensible heat can reach one to two orders of magnitude in some cases.
That is why PCMs store and release large amounts of thermal energy because of their high latent heat storage capacity. A graph of temperature against heat added has a flat stretch: heat keeps going in while temperature stands still.
- Wall without PCM (left, both red arrows equally thick)
- Wall with a PCM layer (right, the outgoing arrow very thin)
- Line dividing the two walls (dashed)
How is a melting point chosen so a PCM works in a building?
The melting point should sit close to the temperature the room is set to. It is beneficial to design the PCM transition temperature as close as possible to the internal space set-point temperature. The reason is that a PCM only absorbs and releases a large amount of heat around its own transition point; if the room never reaches that temperature, the latent heat goes unused.
A numerical model of attic floor insulation gives the following figures. When the PCM melting temperature differs by only 2 °C from the indoor set-point temperature, the daily heat gain through the attic floor is cut by about 35% to 70%. When the difference grows to 7 °C, the saving falls to only about 8% to 10%. This is the result of one model with its own assumptions, not a saving guaranteed for every house.
What kinds of PCM are there, and how do they differ?
The two most familiar kinds in buildings are paraffins and salt hydrates.
Paraffins are the most widely used PCMs in buildings because they are nontoxic, abundant and easy to microencapsulate. For paraffins, melting temperature and phase-change enthalpy increase with the length of the carbon chain, so a grade can be picked to suit the need.
Salt hydrates are the alternative. They are nontoxic, nonflammable and less corrosive, with higher thermal conductivity than organic PCMs, and they melt in the range of 5 to 130 °C, suitable for building applications.
- PCM container (open-topped frame)
- The dissolved liquid part
- Undissolved salt settled at the bottom (grey layer)
- Material still helping to store heat (blue dots)
- Direction of settling (red arrow)
What are the limits of PCMs?
The main limits are cyclic durability, supercooling and scalability: these are some of the major challenges of using PCMs for thermal storage in buildings. In an ORNL test of a commercial organic PCM, the material stayed thermally stable over 200 cycles and the supercooling stayed within 0.2 °C. That is the result for one particular material and says nothing about other PCMs.
Salt hydrates have a problem of their own. Inorganic salts experience incongruent melting: undissolved salt settles to the bottom of the container and does not contribute to heat storage, which reduces the efficiency of the product.
Real-world example
Think of a glass of iced water left in the sun. While there is still ice in the glass, the water stays cold, because heat from outside goes into melting the ice rather than warming the water. When the ice is gone, the water starts to warm. This is only an analogy: a PCM wall melts near room temperature, not at freezing point, and works through many daily cycles.
Common misunderstandings
A PCM makes a wall cold. It absorbs heat, but its temperature stays near its melting point meanwhile; it does not drop further.
Any PCM helps equally. The saving depends strongly on the melting point relative to the room's set-point temperature.
Fit a PCM once and it lasts forever. Cyclic durability is still a challenge.
Frequently asked questions
How does a PCM store heat?
Through latent heat: the heat exchanged when a material changes phase, with no change in temperature.
Why is the latent heat of ice large compared with sensible heat?
Melting ice takes 330 kJ/kg, while changing the temperature of water by 10 K takes only 42 kJ/kg.
What should I look at first when choosing a PCM for a wall?
The melting point: the closer to the internal set-point temperature, the better.
Summary
- A PCM stores and releases a large latent heat at a nearly constant temperature.
- The closer its melting point is to the room's set point, the better it works.
- Paraffins and salt hydrates have different strengths, and PCMs still face durability, supercooling and scale challenges.
Terms in this article
English and Vietnamese terms, with the meanings used here. Hover, tap or Tab to a term with a dotted underline for an explanation as you read.
- phase-change materialvật liệu chuyển pha
- A material that uses its ability to change phase to heat, cool or stabilise temperature.
- latent heatnhiệt ẩn
- The heat tied to a unit mass of material as it changes phase, with no change in temperature.
- sensible heatnhiệt hiển
- The heat needed to change a material's temperature without a phase change.
- paraffinparafin
- The most common organic PCMs in buildings; their melting temperature rises with carbon-chain length.
- salt hydratemuối ngậm nước
- A salt with one or more water molecules in its crystal, used as an inorganic PCM.
- supercoolingquá lạnh
- When a material cools below its freezing point without yet solidifying, a challenge for PCMs.
- incongruent meltingnóng chảy không đồng nhất
- When a salt does not fully dissolve in its own water on melting, so the undissolved part settles at the bottom.
This article is not marked as viewed
Spotted something wrong or unsafe?
Tell the administrator by email. The message already has the article title and address.
More in this topic
IntermediateHow Does Heat Treatment Change a Metal's Properties?
Learn how heating and cooling change steel structure, how martensite and hardenability affect hardness, and why distortion and cracking matter.
5 min read
IntermediateHow Do Thermal Bridges Weaken Insulation?
Heat takes a shortcut through conductive framing, so the whole wall performs worse than its insulation. See how it works and how to break it.
7 min read
IntermediateHow Does Thermal Mass Delay and Soften Heat Swings?
Thermal mass stores and releases heat; time lag, climate and wall design shape indoor temperature swings.
2 min read
IntermediateHow Do Low-E and Multi-Pane Glass Reduce Heat Loss?
Low-e coatings reduce radiant heat transfer, while extra panes and gas-filled gaps affect window heat flow and its U-factor.
2 min read
Sources
These sources are written for older readers. If they feel hard, read them with an adult.
- Multiscale characterization of phase change materials for building thermal energy storage (ORNL)(opens in a new tab)
Oak Ridge National LaboratoryTier A: government, standards or research bodiesRead on November 14, 2026
- Cost analysis of simple phase change material enhanced building envelopes (OSTI)(opens in a new tab)
U.S. Department of Energy OSTITier A: government, standards or research bodiesRead on November 14, 2026